Hep2O 8 Zone Wiring Centre by Wavin

£122.50 inc. of VAT

£102.08 ex. of VAT

£202.46 RRP

39% Saving

MPN: 52UH108

Availability:

free delivery

****PLEASE NOTE item discontinued Heatmiser alternative available please call for details thank you****


     qm8z.jpg


Wavin Hep2O Manufacturer's part number: 52UH108.
Hep2O 8-zone (8 Channel) Underfloor Heating Control Centre - mains operated temperature control centre for up to 8 underfloor heating zones, for use with 12 Volt network thermostats, designed for control of a multi-zone Hep2O UFH systems, both in new build and renovation projects.
The 8 Zone Control Centre is a central wiring switch box designed to be used with 12v network thermostats. 8 Zones can be controlled as well as providing an output for a hot water cylinder. On demand from any zone, a 230v output is provided to switch the relevant zone actuators, underfloor heating pump and valve. A volt free connection is supplied for the boiler, making it compatible with almost all types of boilers. Up to 6 actuators can be connected to each zone.
Hep2O 8-zone Control Centre by Wavin features and benefits:
Allows wiring of up to 14 underfloor heating zones.
Suitable for use with any combination of wired and wireless thermostats, both programmable and non-programmable.
Easy to install.
Easily configurable.
Where wired thermostats are used, they are wired into 2 central terminals in the Hep2O Control Centre at first fix stage, then synchronised with the relevant circuit later, eliminating the chance of cross wiring.
Where wireless thermostats are used - no cable required between thermostat and Control Centre = no disruption to walls during installation.
It is recommended that Control Centre is mounted above the manifold it will be controlling, ensuring the actuator cables reach the actuator terminals without requiring any extension.
Holiday Mode - is enabled by installing a Single Pole, Single Throw (SPST) switch across the SUM and GND terminals on the Hep2O Control Centre. When running in holiday mode the room thermostats will maintain a lower room temperature, saving energy while preventing damp or even frost damage.
LEDs on the Control Centre's front cover indicate the status of each output channel (Red/Green Steady/Flashing/Rapid light).
Only one thermostat can be enrolled to each Control Centre's channel however a thermostat can be enrolled to multiple channels or other receivers without restriction, meaning one thermostat can control multiple UFH zones. If you try to enrol a new thermostat to an occupied channel, the new thermostat will be enrolled, replacing the existing one.
Hep2O 14-zone Control Centre by Wavin Technical Information:
Dimensions (mm): 258 x 214 x 77.
Weight: 1.65kg.
Power supply: 230V, 50Hz via Heating/Pump Fused Spur.
Operating load: Max. 0.2A (0.02A stand-by).
Voltage of COM outputs: 24V DC.
Radio frequency: 868 MHz.
Communication range: 100m (open area).
Operational temperature: -10°C to 40°C.
Please note: The 24V actuator terminals are pulse switched and should therefore only operate thermoelectric actuators. They should not be used to power any motorised valves, relays or semiconductor switches etc.
For more information on Hep2O 14-zone UFH Control Centre by Wavin, please refer to the Hep2O Underfloor Heating Product Guide and Standard Control Systems Datasheet